{"id":1726,"date":"2023-02-09T15:09:56","date_gmt":"2023-02-09T07:09:56","guid":{"rendered":"http:\/\/43.143.253.153:200\/?post_type=product&#038;p=1726"},"modified":"2025-08-22T20:26:34","modified_gmt":"2025-08-22T12:26:34","slug":"ne-starstim%e7%bb%8f%e9%a2%85%e7%94%b5%e5%88%ba%e6%bf%80%e7%b3%bb%e7%bb%9f","status":"publish","type":"product","link":"http:\/\/hengzhikj.com\/en\/product\/ne-starstim%e7%bb%8f%e9%a2%85%e7%94%b5%e5%88%ba%e6%bf%80%e7%b3%bb%e7%bb%9f\/","title":{"rendered":"NE StarStim Transcranial Electrical Stimulation System"},"content":{"rendered":"<table>\n<tbody>\n<tr class=\"firstRow\">\n<td valign=\"top\" width=\"571\">\n<h3><strong>Transcranial direct current stimulation (tDCS)<\/strong><\/h3>\n<p>TDCS is a form of neurostimulation that uses a constant, low current delivered directly to the area of the brain of interest via small electrodes. When these electrodes are placed in the area of concern, the current induces current flow in the cerebral cortex, which can increase or decrease neuronal excitability in specific areas to alter brain functioning.<\/td>\n<td valign=\"top\" width=\"571\"><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-3024 aligncenter\" src=\"http:\/\/everloyal.com.cn\/wp-content\/uploads\/2023\/02\/20170411095718233.jpg\" alt=\"\" width=\"413\" height=\"393\" srcset=\"http:\/\/hengzhikj.com\/wp-content\/uploads\/2023\/02\/20170411095718233.jpg 527w, http:\/\/hengzhikj.com\/wp-content\/uploads\/2023\/02\/20170411095718233-300x286.jpg 300w, http:\/\/hengzhikj.com\/wp-content\/uploads\/2023\/02\/20170411095718233-13x12.jpg 13w\" sizes=\"(max-width: 413px) 100vw, 413px\" \/><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"571\"><img decoding=\"async\" class=\"wp-image-3026 aligncenter\" src=\"http:\/\/everloyal.com.cn\/wp-content\/uploads\/2023\/02\/20170410033623848.jpg\" alt=\"\" width=\"405\" height=\"359\" srcset=\"http:\/\/hengzhikj.com\/wp-content\/uploads\/2023\/02\/20170410033623848.jpg 537w, http:\/\/hengzhikj.com\/wp-content\/uploads\/2023\/02\/20170410033623848-300x266.jpg 300w, http:\/\/hengzhikj.com\/wp-content\/uploads\/2023\/02\/20170410033623848-14x12.jpg 14w\" sizes=\"(max-width: 405px) 100vw, 405px\" \/><\/td>\n<td valign=\"top\" width=\"571\">\n<h3><strong>Historcal review Historical review<\/strong><\/h3>\n<ul>\n<li>As early as 1794, Giovanni Aldini had already evaluated the effects of head currents in his own body, and by 1804 he had already reported the successful treatment of patients suffering from depression<\/li>\n<li>1930s: TDCS was abandoned as other forms of neurostimulation were considered to have more potential (Woods et al., 2010.)<\/li>\n<li>1960: TDCS was found to affect sebum excitability (Woods et al., 2010)<\/li>\n<li>Studies after 2012: TDCS is now better understood and applied under conditions with good imaging and stimulation techniques, (Nitsche et al., 2012 onwards)<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"571\">\n<h3><strong>Bipolar stimulation<\/strong><\/h3>\n<ul>\n<li>When a stimulus has two electrodes, an anode and a cathode, it is referred to as bipolar electrical stimulation. This, in turn, defines the +\/- polarity near each stimulating electrode. tDCS is the most common application when using bipolar montages. This has two potential drawbacks.<\/li>\n<li><span style=\"font-size: 16px; font-family: inherit;\">Anodal stimulation of an electrode is inevitable with a cathodal stimulation electrode (and vice versa), without a reference electrode (safety issue)<\/span><\/li>\n<li><span style=\"font-size: 16px; font-family: inherit;\">Requires a very large electrode covering a large cortical area to produce the electric field Disadvantage is that it is not focused (low precision)<\/span><\/li>\n<\/ul>\n<\/td>\n<td valign=\"top\" width=\"571\"><img decoding=\"async\" class=\"wp-image-3027 aligncenter\" src=\"http:\/\/everloyal.com.cn\/wp-content\/uploads\/2023\/02\/20170410034556888.jpg\" alt=\"\" width=\"558\" height=\"242\" srcset=\"http:\/\/hengzhikj.com\/wp-content\/uploads\/2023\/02\/20170410034556888.jpg 567w, http:\/\/hengzhikj.com\/wp-content\/uploads\/2023\/02\/20170410034556888-300x130.jpg 300w, http:\/\/hengzhikj.com\/wp-content\/uploads\/2023\/02\/20170410034556888-18x8.jpg 18w\" sizes=\"(max-width: 558px) 100vw, 558px\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td colspan=\"3\"><strong>1. Non-invasive wireless transcranial electrical stimulator mainframe<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\n<div>*1.1 Number of electrical stimulation channels.<\/div>\n<div>*1.2 Transmission method.<\/div>\n<div>*1.3 Transcranial electrical stimulation modalities.<\/div>\n<div>1.4 Flow limitation.<\/div>\n<div>1.5 Current accuracy.<\/div>\n<div>1.6 Current accuracy.<\/div>\n<div>1.7 Current stimulation rise and fall.<\/div>\n<div>1.8 Impedance test.<\/div>\n<div>1.9.1 Voltage.<\/div>\n<div>1.9.2 tRNS Amount of stimulus change.<\/div>\n<\/td>\n<td><\/td>\n<td>\n<div>8 channels<\/div>\n<div>Wireless Bluetooth Blue Tooth 2.1<\/div>\n<div>tDCS transcranial direct current stimulation, tACS transcranial alternating current stimulation, tRNS transcranial random noise stimulation, Sham pseudo-stimulation and other modes<\/div>\n<div>+\/-2mA per electrode<\/div>\n<div>&lt;10% (&lt;1% after calibration)<\/div>\n<div>&lt;1 \u03bcA microamp level<\/div>\n<div>Adjustable time<\/div>\n<div>Each of the 8 channels can be tested in real-time impedance<\/div>\n<div>Reach +\/-15V (maximum stimulation potential of 30V)<\/div>\n<div>&lt;640\u03bcA<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>Starstim is an ideal multichannel transcranial electrical stimulation system that provides tDCS, tACS, tRNS, custom waveforms, temporal interference (TI), etc. Starstim provides you with a closed-loop research paradigm that not only provides neural stimulation but also simultaneous EEG signal acquisition.<br \/>\nContact us for details: 010-53352947<\/p>","protected":false},"featured_media":3669,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[28],"product_tag":[],"class_list":["post-1726","product","type-product","status-publish","has-post-thumbnail","hentry","product_cat-28"],"_links":{"self":[{"href":"http:\/\/hengzhikj.com\/en\/wp-json\/wp\/v2\/product\/1726","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/hengzhikj.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"http:\/\/hengzhikj.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"http:\/\/hengzhikj.com\/en\/wp-json\/wp\/v2\/comments?post=1726"}],"version-history":[{"count":0,"href":"http:\/\/hengzhikj.com\/en\/wp-json\/wp\/v2\/product\/1726\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/hengzhikj.com\/en\/wp-json\/wp\/v2\/media\/3669"}],"wp:attachment":[{"href":"http:\/\/hengzhikj.com\/en\/wp-json\/wp\/v2\/media?parent=1726"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"http:\/\/hengzhikj.com\/en\/wp-json\/wp\/v2\/product_cat?post=1726"},{"taxonomy":"product_tag","embeddable":true,"href":"http:\/\/hengzhikj.com\/en\/wp-json\/wp\/v2\/product_tag?post=1726"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}